SAZ
Permissible as single fastening. Permissible load in cracked and non-cracked normal concrete of strength ≥ C20/25. Manufacturer’s information has to be observed strictly (ETA-06/0271).
					galvanized, according to ISO 4042
Stainless steel, according to ASTM 31 Ti / AISI 316 L, BS 320S17 / BS 316S11
					
					
					
					| Артикул | Product | length | 
			 Lmin 
			Minimum drilling depth 
			 | diameter | diameter | 
			 Pzul 
			permissible tractive force 
			 | 
		
			 PzulR30 
			permissible tensile load under the influence of fire (30min) 
			 | 
		
			 PzulR90 
			permissible tensile load under the influence of fire (90min) 
			 | weight | |
|---|---|---|---|---|---|---|---|---|---|---|
| SAZ 6 | 8-13 mm | 43 mm | 12 mm | 6 mm | 2,4 kN | 1,0 kN | 0,4 kN | 3.20 kg/100 | ||
| SAZ 8 | 11-17 mm | 43 mm | 10 mm | 8 mm | 1,6 kN | 0,9 kN | 0,7 kN | 1.40 kg/100 | ||
| SAZ 10 | 13-19 mm | 43 mm | 12 mm | 10 mm | 3,0 kN | 2,3 kN | 1,1 kN | 1.90 kg/100 | ||
| SAZ 12 | 15-21 mm | 43 mm | 14 mm | 12 mm | 3,6 kN | 2,8 kN | 1,4 kN | 2.60 kg/100 | 
| Артикул | Product | length | 
			 Lmin 
			Minimum drilling depth 
			 | diameter | diameter | 
			 Pzul 
			permissible tractive force 
			 | 
		
			 PzulR30 
			permissible tensile load under the influence of fire (30min) 
			 | 
		
			 PzulR90 
			permissible tensile load under the influence of fire (90min) 
			 | weight | |
|---|---|---|---|---|---|---|---|---|---|---|
| SAZ 8E4 | 11-17 mm | 43 mm | 10 mm | 8 mm | 1,6 kN | 0,9 kN | 0,7 kN | 1.40 kg/100 | ||
| SAZ 10E4 | 13-19 mm | 43 mm | 12 mm | 10 mm | 3,0 kN | 2,3 kN | 1,1 kN | 1.90 kg/100 | ||
| SAZ 12E4 | 15-21 mm | 43 mm | 14 mm | 12 mm | 3,6 kN | 2,8 kN | 1,4 kN | 2.60 kg/100 |